Process Step

|
 |

Process Detail and Options

|
 |

Specification

|
 |
 |
 |

1.
|

Incoming Wafer
|
 |

Recieve material from customer
|
 |

|
 |

|
 |
 |

|
 |
 |
 |

2.
|

Incoming QA
|
 |

AQL 1% II
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

3.
|

Mount Wafer on Tape
|
 |

|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

4.
|

Dicing
|
 |

Options:
a. DI water
b. DI water w/ CO²
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

5.
|

Die Pik
|
 |

Pik GED from wafer and load into wafer tray
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

6.
|

Visual Inspection
|
 |

100% inspection
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

7.
|

QC Gate
|
 |

AQL 1% II
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

8.
|

Incoming Chip Capacitor
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

9.
|

Incoming Solder Paste
|
 |

63% Sn-37% Pb
|
 |

|
 |

|
 |
 |

|
 |
 |
 |

10.
|

Incoming Package
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

11.
|

Chip Capacitor Attachment
|
 |

Options:
a. Manual
b. Automatic
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

12.
|

Reflow
|
 |

|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

13.
|

Flux Cleaning
|
 |

DI water w/ cleaner
|
 |

|
 |

|
 |
 |

|
 |
 |
 |

14.
|

Incoming Die Attach Material
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

15.
|

Die Attach
|
 |

Material: Silver-filled organic adhesive
Process options:
a. Automatic process
b. Semi-automatic
c. Manual
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

16.
|

Adhesive Cure
|
 |

Options:
a. Constant temp oven cure
b. Multiple temp steps oven cure
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

17.
|

Die Attach Quality Monitor
|
 |

Options:
a. Stud-pull test
b. Die shear test
c. X-ray
d. Sonoscan
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

18.
|

Plasma Cleaning
|
 |

Options:
a. Ar
b. Ar + O²
|
 |

|
 |

|
 |
 |

|
 |
 |
 |

19.
|

Incoming Wire
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

20.
|

Wire Bond
|
 |

Options:
- Au wire
0.7 mil - 65 micron bond pitch
1 mil - 75 micron bond pitch
1.3 mil - 90 micron bond pitch
- Al wire
0.7 mil - 65 micron bond pitch
1 mil - 75 micron bond pitch
1.25 mil - 85 mil bond pitch
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

21.
|

Wire Bond Quality Monitor
|
 |

Options:
a. Wire pull test
b. Ball shear test
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

22.
|

Visual Inspection
|
 |

100% inspection
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

23.
|

QC Gate
|
 |

AQL 1% II
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

24.
|

Incoming Encapsulation
|
 |

For Fill - Hysol 4450 HF
For Dam - Hysol 4451
|
 |

|
 |

|
 |
 |

|
 |
 |
 |

25.
|

Plasma Cleaning
|
 |

Optional
|
 |

|
 |

|
 |
 |

|
 |
 |
 |

26.
|

Encapsulation
|
 |

Options:
a. Cavity Fill
b. Dam-and-fill
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

27.
|

Cure
|
 |

Options:
a. Constant temp oven cure
b. Multiple temp steps oven cure
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

28.
|

Visual Inspection
|
 |

|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

29.
|

Marking
|
 |

Options:
a. Offset marking
b. White ink
c. Serialization
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

30.
|

Cure
|
 |

|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

31.
|

Flux Transfer
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

32.
|

Incoming Solder Ball
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

33.
|

Ball Attachment
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

34.
|

Flux Cleaning
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

35.
|

Ball Shear Test
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

36.
|

Visual Inspection
|
 |

100% insepction
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

37.
|

Co-planarity Check
|
 |

|
 |

|
 |

|
 |
 |

|
 |
 |
 |

38.
|

QC Gate
|
 |

AQL 1% II
|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

39.
|

Packing
|
 |

|
 |

KS-1001
|
 |

|
 |
 |

|
 |
 |
 |

40.
|

Shipping
|
 |

|
 |

KS-1001
|